Product Test Report
Customer: | Prouct Name: |
HR30 Yellow |
|
Foaming Date: |
20210729 | Test Date: |
20210802 |
Product Physical Test Report
No. |
Technical Parameter |
Unit |
Test Criterion |
Specification |
Actual Data |
Pass/Fail |
1 |
Density |
kg/m³ |
DIN EN ISO845 |
Standard value±3kg/m³ |
27.3 |
Acceptsd |
2 |
Tensile Stemgth |
kpa |
GB/T6344-2008 |
≥80 |
138.9 |
Acceptsd |
3 |
Elongation at Break |
% |
GB/T6344-2008 |
≥90 |
112.2 |
Acceptsd |
4 |
Pressure Wire Hardness |
N |
GB/T10807 |
25% |
83.1 |
Acceptsd |
40% |
110.6 |
Acceptsd | ||||
65% |
210.9 |
Acceptsd | ||||
5 |
Teared Strength |
N/CM |
GBT 10808-2006 |
- |
3.01 |
Acceptsd |
6 |
Springback |
% |
- |
- |
38 |
Acceptsd |
7 |
Compression set |
% |
DIN EN ISO1856 |
≤10% |
5.1 |
Acceptsd |
Test Conclusion: ■Acceptsd □Reject Test Date:2021.08.02 |